SMART SENSORS, WIRELESS & IOT

Our SMART Sensors, Wireless & IoT solutions provide real-time data monitoring and control, enhancing efficiency and accuracy in various applications. With advanced connectivity and intelligent features, they offer seamless integration, remote access, and improved decision-making for modern industrial processes.

PH SENSORS - PH103

  • Measuring range: 0.00~14.00
  • Accuracy: ±0.02PH
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20 MA
  • Protection: IP68
  • Standard cable length: 5m

DO SENSOR - DO103M

  • Measuring range: 0~20mg/L
  • Accuracy: ±1.0%FS
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

CONDUCTIVITY SENSOR - CT103

  • Measuring range: 0~2000μs/cm
  • Accuracy: ±2%FS
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

CHLORINE SENSOR - RCL103

  • Measuring range: 0~20mg/L
  • Accuracy: ±1% or ±0.01mg/L
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

ORP SENSOR - ORP103

  • Measuring range: -1999~+1999mV
  • Accuracy: ±0.02PH / ±0.02mV
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

DISSOLVED OZONE SENSOR - DOZ103

  • Measuring range: 0~20mg/L
  • Accuracy: ±1% or 0.01mg/L
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

CHLORIDE SENSOR - CLD400

  • Measuring range: 1.8~10,000 MG/L
  • Accuracy: ±2.5%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 80℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 5m

AMMONIA SENSOR - NH4103

  • Measuring range: 0.01~1000 PPM
  • Accuracy: ±2.5%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 50℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 5m

FLUORIDE SENSOR - FL103

  • Measuring range: 0.02~2000 PPM
  • Accuracy: ±2.5%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 80℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 5m

DO OPTICAL SENSOR - DO108

  • Measuring range: 0~20mg/L
  • Accuracy: ±2.5%FS
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

NITRATE SENSOR - NO3+

  • Measuring range: 0.5~10000 PPM
  • Accuracy: ±2.5%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 50℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 5m

CALCIUM/HARDNESS SENSOR - CA1999

  • Measuring range: 0~10,000mg/L
  • Accuracy: ±5.0%FS
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

TDS SENSOR - TDS103

  • Measuring range: 0~15,000mg/L
  • Accuracy: ±2.0%FS
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485
  • Protection: IP65
  • Standard cable length: 5m

TURBIDITY SENSOR - TURB103

  • Measuring range: 0~10,000 NTU
  • Accuracy: ±1.0%FS
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m

SUSPENDED SOLIDS SENSOR - TSS103

  • Measuring range: 0~10,000 MG/L
  • Accuracy: ±1.0%FS
  • Power supply: DC12 or 24V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485 / 4-20MA
  • Protection: IP68
  • Standard cable length: 5m
  •  

NITRITE SENSOR - NO3+

  • Measuring range: 0.5~10,000 PPM
  • Accuracy: ±2.5%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 50℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 5m

MLSS-COMBINATION SENSOR - MLSS103

  • Measuring range: 0.0~20,000 MG/L
  • Accuracy: ±1.0%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 10m

SALINITY SENSOR - SALINITY103

  • Measuring range: 0.020.000 mS-cm 1.00.150 moI/L
  • Accuracy: ±2.0%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 60℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 5m

POTASSIUM ION SENSOR - KN103

  • Measuring range: 0.05~10.000 MG/L
  • Accuracy: ±2.5%
  • Power supply: DC24V or 12V
  • Operation temp: 0 ~ 50℃
  • Current output: RS485
  • Protection: IP68
  • Standard cable length: 5m